Expert Restoration Services

Equipment and Technology Used in Restoration Services

Professional restoration contractors deploy a defined set of specialized tools and instruments across water, fire, mold, and structural recovery projects. This page covers the major equipment categories used in the field, the technical principles behind each, the scenarios where specific tools are required, and the classification boundaries that guide equipment selection. Understanding these tools matters because improper equipment selection is a primary cause of incomplete drying, undetected moisture intrusion, and failed remediation outcomes.

Definition and scope

Restoration equipment encompasses the instruments, machines, and monitoring devices used to detect, extract, dry, clean, and document damage in residential, commercial, and industrial structures. The scope spans three functional layers: detection instrumentation (moisture meters, thermal cameras, air sampling devices), mitigation machinery (water extractors, air movers, dehumidifiers, negative air machines), and specialty apparatus (hydroxyl generators, ultrasonic cleaners, freeze-drying chambers for document restoration).

Equipment selection is governed by industry standards published by the Institute of Inspection, Cleaning and Restoration Certification (IICRC), particularly IICRC S500 (Standard for Professional Water Damage Restoration), IICRC S520 (Standard for Professional Mold Remediation), and IICRC S770 (Standard for Professional Sewage Restoration). The U.S. Environmental Protection Agency (EPA) and Occupational Safety and Health Administration (OSHA) impose additional requirements for equipment used during hazardous-material remediation, including asbestos abatement and biohazard cleanup.

How it works

Restoration equipment operates across four sequential phases that structure every professional project:

  1. Detection and assessment — Technicians use non-penetrating and penetrating moisture meters calibrated to wood, concrete, and drywall substrates to map the moisture boundary. Thermal imaging cameras (infrared, typically operating in the 8–14 µm long-wave spectrum) identify temperature anomalies that indicate hidden moisture behind wall cavities without destructive investigation. Moisture mapping produces a baseline document that guides all downstream drying decisions.

  2. Extraction — Truck-mounted or portable extractors remove standing water. Truck-mounted units typically generate between 200 and 500 inches of water lift and 200 to 400 CFM of airflow, giving them substantially greater extraction capacity than portable units, which commonly operate between 100 and 200 inches of water lift.

  3. Structural drying — Axial and centrifugal air movers direct high-velocity airflow across wet surfaces to accelerate evaporation. Low Grain Refrigerant (LGR) dehumidifiers then capture water vapor from the air, typically removing 30 to 90 pints of water per day depending on unit class and ambient conditions. IICRC S500 classifies drying systems by grain depression targets rather than by equipment brand or model, which standardizes the outcome measure regardless of the specific hardware deployed. Drying equipment selection is tied directly to water damage category and class as defined in S500.

  4. Verification and documentation — Final moisture readings confirm that structural materials have returned to acceptable equilibrium moisture content (EMC) levels. Data loggers record temperature and relative humidity continuously throughout the drying period, producing timestamped records for insurance and quality documentation purposes.

Common scenarios

Different loss types drive distinct equipment configurations:

Decision boundaries

Equipment selection follows classification logic, not default checklists. The IICRC S500 Water Damage Class system (Class 1 through Class 4) determines the drying assembly and equipment density: Class 1 losses affect only part of a room with minimal absorption; Class 4 losses involve specialty drying for hardwood floors, concrete slabs, or structural assemblies where standard air movers are insufficient and desiccant dehumidification may be required.

A critical contrast exists between refrigerant dehumidifiers and desiccant dehumidifiers. Refrigerant units are most effective when ambient temperatures exceed 70°F and relative humidity is above 60%; their performance degrades in colder conditions. Desiccant units use silica gel or similar hygroscopic media to absorb moisture regardless of temperature, making them the appropriate choice for cold-climate projects, crawl space drying in winter, or freezer/cold storage restoration.

Projects involving asbestos abatement or lead paint remediation carry additional equipment mandates under EPA National Emission Standards for Hazardous Air Pollutants (NESHAP) and EPA's Renovation, Repair and Painting (RRP) Rule respectively, including HEPA-equipped vacuums and sealed containment systems. Equipment deployed outside these compliance boundaries creates regulatory liability independent of remediation outcome quality.

Provider credentials and equipment verification are covered in restoration services contractor credentials and IICRC standards for restoration.

References

On this site

Core Topics
Contact

In the network